Copeland compressor nomenclature. units. However, the level and nomenclature of a compressor includes the following parameters: Aug 31, 2017 · Nomenclature Copeland Scroll tandem compressor units Published 08/31/2017 04:14 PM | Updated 12/20/2021 07:07 PM Are you confused by the nomenclature when dealing with Copeland Scroll tandem compressor units? Copeland Scroll Digital compressors have one Scroll compression set driven by a single- or three-phase induction motor. The new compressor can be selected based on the same criteria to ensure compatibility with the existing system, preventing unnecessary downtime or installation issues. note: nominal horsepower rating of 100 = std. • For A3 refrigerants (R290) remove refrigerant from both the high and low sides of the compressor. ) CR Service Compressor Kit Guide Nov 6, 2017 · There is much information about a compressor that can be obtained from decoding its model number. During the loaded state, the compressor delivers 100% capacity and during the unloaded state, the compressor delivers 0% capacity. Particular emphasis has been placed on the user’s safety. T D = 380 Figure 1 : Exemple de nomenclature pour un compresseur scroll standard de la gamme ZR Z R 48 K 3 E – T F D - 522 Emerson Global | Emerson Copeland_discus_model_chart. 2 Nomenclature The model designation contains the following technical information about the copelameticâ compressor model number nomenclature compressor cooling code description a air cooled d discus r refrigerant cooled t std. pdf), Text File (. two stage w water cooled may be (-) or a model variations a number assigned to indicate major variations within any one family series. Learn how to identify and decode the nomenclature of Copeland AC compressors. Plus de détails concernant la nomenclature en fonction des modèles et familles sont disponibles dans les guides d’applications. a external inherent protection. * Standard and Premium Service Kits are not sold separately, part numbers for reference only. 800 = std. replacement compressor and component. and component parts 201 = 201 and larger will be assigned for all other variations. 801 = std. The scroll set is mounted at the upper end of the rotor shaft of the motor. P. 4°C) condensing temperature. Note that Stream 4M* and 6M* compressors are covered in a different manual see – AGL_Stream_ST_A2L_A1_4M_6M_EN "Copeland™ Stream Semi-Hermetic Compressors". The document provides a nomenclature chart for Copeland Discus compressors that explains the codes used to identify key product details like application range, variations, capacity, electrical specifications, and protection features in 3 letters or fewer. used in copeland cond. pdf - Free download as PDF File (. rcpsrl. Copeland semi-hermetic compressors are suitable for a wide range of applications in the form of either single compressors, condensing units or as multi-compressor equipment. It is the most efficient and durable compressor Emerson has ever developed for air-conditioning and refrigeration. use Nomenclature The Copeland “CS” compressor model numbers include the nominal capacity at the standard ARI 60Hz rating conditions (R404A Refrigerant). comp. These kits are defined by the last digit of the compressor nomenclature’s Bill of Material (BOM). com Mar 24, 2025 · In the event that a compressor needs to be replaced or upgraded, understanding the numbers on the original Copeland compressor allows for a seamless transition. See Figure 3. 120 volt control. 4 4 R3) REPRESENTS THE COMPRESSOR FAMILY SERIES AND INDICATES TANDEM COMPRESSOR DIGIT 3 DISPLACEMENT AND VALVE PLATE A The scroll nomenclature, as given on the nameplate of the compressor, contains information such as compressor model family, application, capacity and other specifications. 2°C) evaporating temperature and 130°F (54. Use a recovery Nomenclature The model numbers of the Copeland Scroll UltraTech compressors include the approximate nominal 60 Hz capacity at AHRI operating conditions of 45°F (7. Every compressor manufacturer has its own nomenclature for its series of compressors. . Standard Model 3 H. Other available information includes : A/C Compressor Product Guide (2008ECT-113) ZPK5 Product Brochure (2004ECT-182 R5) See full list on cdn. A cycle consists of one loaded state and one unloaded state. Copeland™ Service CR Compressor Cross Reference Guide Copeland™ Three Phase Compressor Models TONNAGE CR6/5 Ton CRKQ CR7 CR1,2,3 CRKF CRKH ZRK5/K3 1. one protector, (line break). Again, this can be a valuable aid for a technician when trying to select a replacement component. 200 = std. Please refer to product literature for specific model number details. The rotor shaft axis is in the vertical plane. • Keep all non-essential personnel away from the compressor during service. 1 Common information about Copeland Scroll™ compressors The Scroll compressor has been under development at Emerson since 1979. By varying the time of the loaded state and the Compressor technology: C = Discus R = Reed valve (old) S = Reed valve (current) Two-s Motor protection: W = Electric motor protection With thermistors and Kriwan module D = DWM Copeland Compressor body - Nr of cylinders 2 cylinders 3 cylinders 6 cylinders 8 c linders Compressor technology: D = Discus T = Two-stage Compressor version Copeland scroll compressors are manufactured according to the latest relevant European, UK and US safety standards. 2. Use a recovery We would like to show you a description here but the site won’t allow us. These application guidelines deal with all vertical single Copeland Scroll compressors for A/C DUTY COMPRESSORS COPELAMETIC R12, R22, R502 Nom. The ZR*KRE compressors are intended for installation in systems in accordance with the following directives and regulations: Oct 13, 2023 · In the global market, there are many types and brands of refrigerant compressors, so the nomenclature of each type of compressor is different. Our free and easy-to-use mobile apps put the information you need at your fingertips. txt) or view presentation slides online. This database includes both air conditioning and refrigeration products used in a variety of HVACR applications. Copeland_discus_model_chart. (Premium Service Kits - offered for selected models only. Operating Envelope There are various refrigerants that have been approved for Aug 31, 2017 · Nomenclature Copeland Scroll tandem compressor units Published 08/31/2017 06:14 AM | Updated 12/20/2021 08:07 AM Are you confused by the nomenclature when dealing with Copeland Scroll tandem compressor units? Un exemple de la nomenclature des compresseurs scroll à vitesse fixe est donné ci-dessous. The BOM (Bill of Material) indication is part of the nomenclature. 5T CR18K6-TF5 CR18KQ-TF5 CRA1-0150-TF5 CRA1-0150-TFC CR18K6-TFD CR18KQ-TFD CRA1-0150-TFD 2T CR22K6-TF5 CRC1-0175-TF5 ZR21K5-TF5 CR22K6-TFD ZR21K5-TFD CR24K6-TF5 CR24KQ-TF5 CRD1-0200-TF5 ZR25K5-TF5 • Allow time for the compressor to cool before servicing. DIGIT1 COMPRESSOR FAMILY SERIES EITHER A NUMBER OR LETTER ESTABLISHED FOR EACH PRODUCT MODEL DIGIT 2 COMPRESSOR TYPE A = STANDARD AIR COOLED D = DISCUS REFRIGERANT COOLED R = STANDARD REFRIGERANT COOLED T = TWO STAGE W = STANDARD WATER COOLED A DIGIT IN THIS POSITION (e. 240 volt control. - Ensure that materials and wiring do not touch high temperature areas of the compressor. COPELAMETIC R12, R22, R502 507 Electrical Data Copeland Scroll compressor nomenclature ZP D 42K 5 E– T F D –130 Z scroll family series AC, R-410A D = Digital S = UltraTech • Allow time for the compressor to cool before servicing. ARJ84C1-IAA* 0058-35 0036-08 0166-38 0001-80 0605-01 C100-06 C001-00 ARJ84C2(E)-IAA* 0058-35 0036-08 0166-38 0001-80 0605-01 C100-06 C001-00 ARJ84C2(E)-IAV* 0061-27 0036-03 0172-02 0102-04 0604-11 0604-11 C001-00 ART51C1(E)-IAA* 0053-35 0038-04 0171-04 C411-80 0603-02 C100-19 C001-00 ART51C1(E)-IAG* 0053-36 0038-05 0171-00 C411-58 0603-06 N/A C001-00 ART51C1(E)-IAV* 0061-13 0008-65 0171-02 Copeland Scroll ZPK5 service compressors are offered in an 800 bill-of-material option, such as ZP25K5E-PFV-800 that includes the compressor with a 42 inch molded plug wiring harness, mounting parts and installation instructions. Find the compressor family series, capacity, motor type, protection type, and other features of different models. g. • Allow time for the compressor to cool before servicing. Use a recovery 2. An example would be the ZPS49K5E-PFV which has 49,100 Btu/hr (14. H. 4 kW) Figure 1 – ZPS*K4 Figure 2 – ZPS*K5 compressor motor continues running, but since the scrolls are separated, there is no compression. The following overview shows an example of the structure of the nomenclature for a fixed-speed scroll Copeland Mobile Copeland™ Mobile App (July 31, 2014) The Copeland Mobile smartphone app provides on-the-go access to Emerson Climate Technologies Online Product Information (OPI) database for Copeland compressor specifi cations. urnnb rdl iurymdov fqoy cpjyq dzjv hton tgeg qsabc hhqpqmtv